D-500 MK2 is a next generation genset controller combining multi-functionality and wide communication capabilities together with a reliable and low-cost design. The same controller provides synchronization, load share, AMF, ATS, Remote Start, Engine Control and Remote Display Panel functionalities. The module comes ready for remote monitoring over GSM or Ethernet with plug-in communication modules.
Various plug-in modules provide unlimited expansion capabilities allowing to meet any special requirement. The unit complies and mostly exceeds world’s tightest safety, vibration and environmental standards for the industrial category. Software features are complete with easy firmware upgrade process through USB port. The Windows based PC software allows monitoring and programming through USB, RS-485, Ethernet and GPRS. The Rainbow Scada web monitoring service allows monitoring and control of an unlimited number of gensets through any web browser.
FUNCTIONALITIES:
- Multi genset synchronizer and load share
- Multi genset mains synchronizer
- Single genset parallel with mains
- AMF unit with uninterrupted transfer
- ATS unit with uninterrupted transfer
- Remote start controller
- Manual start controller
- Engine controller
- Remote display & control unit
- Waveform display of V & I
- Harmonic analysis of V & I
COMMUNICATION:
- Ethernet port (10/100Mb)
- GSM-GPRS
- Embedded web server
- Web monitoring
- Web programming
- Central Monitoring through internet
- SMS message sending
- E-mail sending
- Central monitoring
- Modbus RTU through RS-485
- Modbus TCP/IP
- SNMP
- USB Host
- CANBUS-2 for inter- module comm.
- USB Device
- PC software: Rainbow Plus
- J1939-CANBUS for electronic engines
FEATURRES:
• Diesel and gas genset support
• 400Hz operation support
• 400 event logs, full snapshot
• All parameters front panel editable
• 3 level configuration password
• 128x64 graphical LCD display
• Downloadable languages
• Waveform display of V & I
• Harmonic analysis of V & I
• Synchroscope & check synch
• Allows closed transfers
• 16Amp MCB & GCB outputs
• 8 configurable digital inputs
• Inputs expandable to 40
• 8 configurable digital outputs
• Outputs expandable to 40
• 7 configurable analog inputs
• Both CANBUS-J1939 & MPU
• 3 configurable service alarms
• Multiple topologies
• 6xCT, true mains metering
• Supports up to 48 gensets
• Automatic learning/self adjust
• Direct governor & AVR control
• Voltage and phase matching
• kW & kVAr load sharing
• True soft transfer in both ways
• PLC functions
• Peak Lopping / peak shaving
• Mains de-coupling protection
• R.O.C.O.F protection
• Vector shift protection
• Reverse power protection
• Over/under freq. Protection
• Over/under voltage protection
• Smart load management
• Smart genset sequencing
• Run/stop priority support
• Equal aging of gensets
• Base load (power export)
• Unmanaged distributed power export support
• AVR & GOV droop support
• Dead bus sensing
• Multiple automatic exerciser
• Weekly operation schedule
• Dual mutual standby with equal aging of gensets
• Manual “speed fine adjust” on selected ECUs
• Automatic fuel pump control
• Disable protections feature
• Excess power protection
• Reverse power protection
• Overload IDMT protection
• Load shedding, dummy load
• Multiple load management
• Current unbalance protection
• Voltage unbalance protection
• Fuel filling & fuel theft alarms
• Contactor & MCB drive
• Battery back-up real time clock
• Idle speed control
• Battery charge run enabled
• Combat mode support
• Multiple nominal conditions
• 4 quadrant genset power counters
• Mains power counters
• Fuel filling counter
• Fuel consumption counter
• Modem & ethernet diagnostics
• Configurable through USB, RS-485, Ethernet and GPRS
• Free configuration program
• Allows SMS controls
• Ready for central monitoring ethernet & GPRS
• Mobile genset support
• Automatic GSM geo-location
• GPS connectivity (USB&RS232)
• Dynamic DNS support
• Easy USB firmware upgrade
• IP65 rating with standard gasket
TECHNICAL SPECIFICATIONS:
Alternator voltage: 0 to 300 V-AC (Ph-N)
Alternator frequency: 0-600 Hz.
Mains voltage: 0 to 300 V-AC (Ph-N)
Mains frequency: 0-600 Hz.
Topology: 1-2-3 phases, with or without neutral
DC Supply Range: 8.0 to 36.0 V-DC.
V-A-cos Accuracy: 0.5% + 1 digit
kW-kVA-kVAr Accuracy: 1.0% + 1 digit
Current consumption: 500 mA-DC max.
Current Inputs: from current transformers. ../5A or ../1A.
Digital inputs: input voltage 0 to 36 V-DC.
Analog input range: 0-5000 ohms.
Mains and genset contactor outputs: 16Amps@250V
DC Outputs: Protected mosfet semiconductor outputs,
rated 1Amp@28V-DC
Cranking dropouts: survives 0V for 100ms.
Magnetic pickup voltage: 0.5 to 50Vpk.
Magnetic pickup frequency: 0 to 20000 Hz.
Charge Alternator Excitation: 2W.
Display Screen: 2.9”, 128x64 pixels
Ethernet Port: 10/100 Mbits
USB Device: USB 2.0 Full speed
USB Host: USB 2.0 Full speed
RS-485 Port: selectable baud rate (2400-115200baud)
RS-232 Port: selectable baud rate (2400-115200baud)
Operating temperature: -20°C to 70°C (-4 to +158 °F)
Storage temperature: -40°C to 80°C (-40 to +176°F)
Maximum humidity: 95% non-condensing.
IP Protection: IP65 from front panel, IP30 from the rear (with
gasket)
Dimensions: 211 x 162 x 42mm (WxHxD)
Panel Cut-out Dimensions: 176 x 121 mm minimum.
Weight: 500 g (approx.)
Case Material: High Temperature, non-flammable ABS/PC
Installation: Flat surface mounting on a Type 1 enclosure. Rear
retaining plastic brackets.
CONFORMITY:
EU Directives Conformity
-2014/35/EC (low voltage)
-2014/30/EC (electro-magnetic compatibility)
Norms of reference:
EN 61010 (safety requirements)
EN 61326 (EMC requirements)
UL & CSA Compatibility:
• UL 6200, Controls for Stationary Engine Driven Assemblies
(File# - 20140725-E314374)
• CAN/CSA C22.2 No. 14-13 – Industrial Control Equipment
WE DO NOT SHIP THIS PRODUCT TO USA AND CANADA